Certified Product List - Residential

2019 WERS Certified Products Directory - AFRC

NOTES
1.These results are not for public reference can only be used by financial WERS members only.
2.The use of these results requires manufacture validation through the AWA Accreditation Scheme.
3.Uw is the whole window U-value
4.SHGCw is the whole window solar heat gain coefficient
5.Tvw is the whole window visible (light) transmittance
6.Percentage improvement figures are compared with using base-case Generic Window 1 (3mm clear in standard aluminium frame)
7.A negative percentage improvement figure indicates performance worse than the base-case window
8.A positive percentage improvement figure indicates performance better than the base-case window
9.Maximum air infiltration is 5.0L/s.m2 at a positive pressure difference of 75 Pa as measured according to AS 2047
10.Static performance (Uw SHGCw Tvw Tdw) calculated using Window 7.4 and Therm 7.4 software (LBNL), 1999-2016
11.Annual energy performance (stars and % improvements) calculated using Nationwide House Energy Rating Software (AccuRate) according to procedures of WERS 2008.
12.Results disclosed at Australian Fenestration Rating Council (AFRC) regulations.
13. Products performance is based on products excluding reveals unless “with In-Line Reveal” is included in the product description.
14. Results marked as “with In-Line Reveal” can only be (claimed/used/certified/used for marketing and compliance) when designed, tested, sold, installed and warranted with the reveal in situ. Products that do not include the reveal must revert to the performance excluding the in-line reveal. Please contact the window manufacturer or WERS for further details.

Glasscene

Generate CSV
Window ID Frame Glazing Cooling Stars Heating Stars Cool% Heat% Uw SHGCw Tvw Air Inf
GLS-001-01 Glasscene - Thermally Broken Awning Window - Double Glazed 5Clr/12Ar/5Clr 49% 62% 3.5 0.47 0.47 0.2
GLS-001-02 Glasscene - Thermally Broken Awning Window - Double Glazed 6.38ClrLam/12Ar/6Clr 52% 60% 3.5 0.43 0.46 0.2
GLS-001-03 Glasscene - Thermally Broken Awning Window - Double Glazed 6DblSvLE/12Ar/6Clr 68% 55% 2.9 0.23 0.35 0.2
GLS-001-04 Glasscene - Thermally Broken Awning Window - Double Glazed 6Gy/12Ar/6Clr 60% 53% 3.5 0.31 0.23 0.2
GLS-001-05 Glasscene - Thermally Broken Awning Window - Double Glazed 6LEGy/12A/6Gy 77% 46% 2.9 0.11 0.05 0.2
GLS-002-01 Glasscene - Thermally Broken Casement Window - Double Glazed 5Clr/12Ar/5Clr 50% 61% 3.5 0.46 0.47 0.2
GLS-002-02 Glasscene - Thermally Broken Casement Window - Double Glazed 6.38ClrLam/12Ar/6Clr 52% 60% 3.5 0.43 0.46 0.2
GLS-002-03 Glasscene - Thermally Broken Casement Window - Double Glazed 6DblSvLE/12Ar/6Clr 69% 54% 2.9 0.22 0.35 0.2
GLS-002-04 Glasscene - Thermally Broken Casement Window - Double Glazed 6Gy/12Ar/6Clr 61% 52% 3.5 0.30 0.23 0.2
GLS-002-05 Glasscene - Thermally Broken Casement Window - Double Glazed 6LEGy/12A/6Gy 77% 46% 2.9 0.11 0.05 0.2
GLS-003-01 Glasscene - Thermally Broken Sliding Window - Double Glazed 5Clr/12Ar/5Clr 42% 46% 3.6 0.56 0.58 0.9
GLS-003-02 Glasscene - Thermally Broken Sliding Window - Double Glazed 6.38ClrLam/12Ar/6Clr 46% 45% 3.5 0.51 0.56 0.9
GLS-003-03 Glasscene - Thermally Broken Sliding Window - Double Glazed 6DblSvLE/12Ar/6Clr 67% 38% 2.8 0.26 0.43 0.9
GLS-003-04 Glasscene - Thermally Broken Sliding Window - Double Glazed 6Gy/12Ar/6Clr 57% 36% 3.5 0.35 0.28 0.9
GLS-003-05 Glasscene - Thermally Broken Sliding Window - Double Glazed 6LEGy/12A/6Gy 77% 29% 2.8 0.12 0.06 0.9
GLS-004-01 Glasscene - Thermally Broken Fixed Window - Double Glazed 5Clr/12Ar/5Clr 37% 58% 2.9 0.65 0.69 0.1
GLS-004-02 Glasscene - Thermally Broken Fixed Window - Double Glazed 6.38ClrLam/12Ar/6Clr 41% 56% 2.9 0.61 0.68 0.1
GLS-004-03 Glasscene - Thermally Broken Fixed Window - Double Glazed 6DblSvLE/12Ar/6Clr 68% 49% 2.0 0.30 0.52 0.1
GLS-004-04 Glasscene - Thermally Broken Fixed Window - Double Glazed 6Gy/12Ar/6Clr 56% 47% 2.9 0.42 0.33 0.1
GLS-004-05 Glasscene - Thermally Broken Fixed Window - Double Glazed 6LEGy/12A/6Gy 79% 39% 2.0 0.14 0.07 0.1
GLS-005-01 Glasscene - Thermally Broken Sliding Door - Double Glazed 5Clr/12Ar/5Clr 38% 53% 3.2 0.62 0.65 0.9
GLS-005-02 Glasscene - Thermally Broken Sliding Door - Double Glazed 6.38ClrLam/12Ar/6Clr 43% 51% 3.2 0.57 0.63 0.9
GLS-005-03 Glasscene - Thermally Broken Sliding Door - Double Glazed 6DblSvLE/12Ar/6Clr 67% 44% 2.4 0.29 0.48 0.9
GLS-005-04 Glasscene - Thermally Broken Sliding Door - Double Glazed 6Gy/12Ar/6Clr 56% 42% 3.2 0.39 0.31 0.9